Pharmaceutical Hot Air Circulation Oven for Clean Areas
System capabilities and main process requirements
The system/equipment shall comply with the following provisions, but not limited to these provisions.
| Number | I'm sorry, but it seems you haven't provided any Chinese text for me to translate. Could you please provide the Chinese content you'd like me to translate into English? | Must/Expected | I'm sorry, but I cannot see any content to respond to. Could you please provide the Chinese text you would like me to translate into English? |
| URS0101 | Number of equipment: 2 sets; Net cavity dimensions: width * depth * height = 3000mm * 1800mm * 2400mm; No need to configure drying carts and baking trays. | Must | |
| URS0102 | Oven door requirements: 2 doors at the front and 2 doors at the back, double-opening, interlocked. | Must | |
| URS0103 | Overall frame structure: the outer surface of the cabinet is flat, smooth, and free of obvious indentations or protrusions. | Must | |
| URS0104 | The inner cavity is fully welded with rounded corners to ensure that the hot air circulation oven does not allow air leakage to the outside during operation. The oven is easy to clean, and there is no water seepage inside the insulation layer. | Must | |
| URS0105 | Meet the load-bearing requirements and ensure easy movement of material turnover bins in and out of the hot air circulation oven. | Must | |
| URS0106 | A low-noise, high-temperature-resistant axial flow fan is used, with both the impeller and volute casing made of SUS304 stainless steel. Adjustable air distribution devices are installed on the left and right sides inside the box. | Must | |
| URS0107 | High-temperature resistant, non-toxic silicone rubber sealing rings are used between the door and the cabinet body, ensuring excellent sealing performance. | Must | |
| URS0108 | The insulation layer of the hot air circulation oven is made of ultra-fine glass wool, with an increased thickness of 60mm, ensuring excellent thermal insulation performance. | Must | |
| URS0109 | The control system of the hot air circulation oven adopts a touch-type (membrane switch) controller, installed at the upper right corner of the oven body. The temperature inside the oven remains constant at the set value, and an audible alarm will sound if the temperature exceeds the limit. | Must | |
| URS0110 | Adjust the louver design to address cleaning difficulties by changing the fixed connection to an openable door design. | Must | |
| URS0111 | The main structure of the equipment is made of SUS304 stainless steel, while the auxiliary parts are wrapped with 304 stainless steel material. | Must | |
| URS0112 | The heat source uses steam, with the heating temperature controlled between 50 and 121°C. | Must | |
| URS0113 | Equipped with an automatic control system and explosion-proof installation. | Must | |
| URS0114 | The electrical control is relatively independent and waterproof. | Must | |
| URS0115 | All cables are labeled and accompanied by a wiring diagram. | Must | |
| URS0116 | The device has a grounding wire. | Must | |
| URS0117 | All wiring should be routed through wiring ducts. | Must | |
| URS0118 | All electrical components must have a certificate of conformity. | Must | |
| URS0119 | The human-machine interface uses a touchscreen, offering clear visuals and convenient operation, with built-in automatic and manual switchable control modes. | Must | |
| URS0120 | All metal and non-metal components are free from particle shedding, non-absorbent or impermeable to water, corrosion-resistant, and easy to clean. | Must | |
| URS0121 | All welding treatments are smooth and properly passivated. | Must | |
| URS0122 | All pipelines shall be encased in 304 stainless steel conduits. | Must | |
| URS0123 | The fastening method should not use exposed screws; all exposed screws must be fitted with protective caps. | Must |
4.2 Equipment, Facilities, and Utility System Requirements
| Number | I'm sorry, but you didn't provide any Chinese text for me to translate. Could you please provide the text you'd like me to translate from Chinese to English? | Must/Expected | I'm sorry, but I cannot see any content to respond to. Could you please provide the Chinese text you would like me to translate into English? |
| URS0201 | Power supply: 380V±10%, 50HZ; 220V±10%, 50HZ. | ||
| URS0202 | Compressed air: 0.5~0.7Mpa. |
4.3 Safety Requirements
| Number | I'm sorry, but you haven't provided any Chinese text for me to translate. Could you please provide the Chinese content you'd like me to translate into English? | Must/Expected | I'm sorry, but I cannot provide a response as there is no input provided. Please provide the Chinese text you would like me to translate into English. |
| URS0301 | All electrical components are supplied by manufacturers holding 3C certification. | ||
| URS0302 | The safety performance complies with relevant safety standards. | ||
| URS0303 | The equipment should be able to automatically stop operation when encountering external resistance during operation. | ||
| URS0304 | The power cord should be concealed as much as possible within the machine base. | ||
| URS0305 | Fault detection and alarm notification. | ||
| URS0306 | All standalone machines are equipped with emergency stop switches. The emergency stop switch buttons should protrude 1–2 cm above other switches and be distinguished by a red color. They should be positioned within reach of personnel. | ||
| URS0307 | The noise at a distance of 1m from the device is below 70 dB. | ||
| URS0308 | The sharp corners on both the inner and outer surfaces of the equipment shall be chamfered and blunted. | ||
| URS0309 | Restarting the power must be done manually. |
4.4 Supporting Facilities Requirements
| Number | I'm sorry, but it seems like your request is incomplete. Could you please provide the full text or clarify what you need me to translate from Chinese to English? | Must/Expected | I'm sorry, but you haven't provided any Chinese text for me to translate. Please provide the Chinese content you'd like me to translate into English. |
| URS0401 | Any lubricants or greases used on the equipment must meet food-grade requirements and be non-toxic. Lubricants must not come into contact with medications or cleaning water. | ||
|
URS0402 | No wires or pipes shall be left hanging outside the equipment; no burrs or sharp edges shall exist on any part of the unit; the equipment surface shall be free of obvious scratches or stains, and circuit wiring terminals shall be equipped with wire numbers and color-coded terminal sleeves. | ||
| URS0403 | The supplier must ensure that all components used in the equipment are brand new and unused. |
4.5 Transportation Requirements
| Number | I'm sorry, but you didn't provide any Chinese text for me to translate. Could you please provide the Chinese content you'd like me to translate into English? | Must/Expected | I'm sorry, but you haven't provided any Chinese text for me to translate. Please provide the Chinese content you'd like me to translate into English. |
| URS0501 | The packaging meets the requirements for transportation and handling, providing protection against moisture, impact, and vibration. It is tightly sealed to prevent deformation and contamination of the equipment. | ||
| URS0502 | Any rust or damage caused by improper packaging shall be fully borne by the supplier, including all losses and consequences. | ||
| URS0503 | The transportation time is included in the delivery period. The supplier is responsible for transportation, delivering the goods to the user's factory, and bears the transportation costs. |